Emergency War Surgery NATO Handbook: Part II: Response of the Body to Wounding:
Chapter IX: Shock and Resuscitation
Hemostasis
United States Department of Defense
Early in the evaluation and resuscitation phase of the unstable casualty, extremity
dressings should not be removed, as the ensuing bleeding will only serve to further
deplete circulating volume and will impede therapy by diverting attention away from the
business at hand. Direct pressure will adequately control most external hemorrhage. Blind
clamping in deep wounds is usually time consuming and frustrating, and in general should
be avoided. Tourniquets should be used only after other methods of control have failed. If
indicated, the properly applied tourniquet can save the life, but endangers the limb. A
common mistake with tourniquets is inadequate compression, which occludes the veins but
fails to occlude the artery, resulting in all increased rate of blood loss. The tourniquet
should be placed as distally as possible on the extremity, just proximal to the wound.
Once in place and adequately controlling hemorrhage, it should not be released until the
casualty reaches the operating room. When applied in the field or enroute, the time of
tourniquet application should be recorded on the field medical card.
Expedient evacuation of the shock casualty to a definitive facility should not be
delayed by application of military antishock trouser (MAST). Some controversy still
surrounds their use. MAST trousers can produce ischemia and compartment syndromes if
improperly used. A recent combat casualty with abdominal wounds and no lower extremity
wounds was treated with MAST trousers in addition to fluid resuscitation and operation.
Instability was such that the trousers were left inflated for 18 hours. This casualty
subsequently required bilateral above knee amputations. The trousers should never be
inflated beyond 100 mm Hg. If there has not been a hemodynamic response within 30 minutes,
the inflation pressure should be reduced as the resuscitation continues.
Operation in the resuscitation area of the hospital is rarely necessary; however, the
casualty that arrives with penetrating or perforating chest wounds and very recent loss of
vital signs is an exception. Salvage may be attempted by immediately opening the unprepped
chest of the unanesthetized casualty in an attempt to temporarily control hemorrhage, as
fluids are pumped in and the casualty is ventilated via endotracheal tube. An occasional
young man will be salvaged in this manner. If some degree of stability is achieved, the
casualty is moved to the operating room for definitive repair and closure.
Autotransfusion devices may be available in future wars. There are basically two types
of such devices. Both add small amounts of anticoagulant to the collected blood. One
simply collects the blood, filters it and reinfuses it. The other type collects the shed
blood. washes and centrifugally separates out the red blood cells, and then reinfuses
them. These devices may be practical in the resuscitation area for casualties with
substantial and ongoing hemothorax. In the operating room, these devices may be applicable
in extremity wounds or in cases of uncontaminated hemoperitoneum.
Approved for public release; Distribution is unlimited.
The listing of any non-Federal product in this CD is not an
endorsement of the product itself, but simply an acknowledgement of the source.
Operational Medicine 2001
Health Care in Military Settings
Bureau of Medicine and Surgery
Department of the Navy
2300 E Street NW
Washington, D.C
20372-5300 |
Operational Medicine
Health Care in Military Settings
CAPT Michael John Hughey, MC, USNR
NAVMED P-5139
January 1, 2001 |
United States Special Operations Command
7701 Tampa Point Blvd.
MacDill AFB, Florida
33621-5323 |
This web version is provided by
The Brookside Associates Medical
Education Division. It contains original contents from the official US
Navy NAVMED P-5139, but has been reformatted for web access and includes
advertising and links that were not present in the original version. This web
version has not been approved by the Department of the Navy or the Department of
Defense. The presence of any advertising on these pages does not constitute an
endorsement of that product or service by either the US Department of Defense or
the Brookside Associates. The Brookside Associates is a private organization,
not affiliated with the United States Department of Defense.
Contact Us · ·
Other Brookside Products
|